March 17, 2014
These custom single expansion joints were manufactured for a rare isotopes beams lab at Michigan State University. They are 1″ and 1-1/2″ in diameter and fabricated entirely of 304 stainless steel. The expansion joints are capable of 1″ movement, 380 lb. and 150 psig at 400°F. Dye penetrant exam and helium leak test was conducted prior to shipment.